Cod. G522433
© Copyright 2009, Alliance Laundry System LLC – DO NOT COPY OR TRANSMIT Rev. 00/0510
Technical Information 11
1.4. Electrical requirements
In brackets: specific values for USA / CANADA
HEATING
(*1)
TOTAL
POWER
TOTAL
CONSUMP.
SWITCH
CURRENT
CONDUCTOR
(*2)
VOLTAGE
kW A A mm
2
(AWG)
200V
3ph
H / V 11 31.8 40
10 x 3 +
11 30.5 40
10 x 3 +
208V
3ph
H / V
(11) 30.5 40 8 x 3 + GND
220V
3ph
H / V
11 2809 40
10 x 3 +
230V
3ph
H / V
11 27.6 40
10 x 3 +
11 26.5 40
10 x 3 +
240V
3ph
H / V
11 26.5 40 8 x 3 + GND
380V
3ph
H / V
11 16.7 25
6 x 3 +
400V
3ph
H / V
11 15.9 25
6 x 3 +
415V
3ph
H / V
11 15.3 25
6 x 3 +
11 14.4 20
6 x 3 +
440V
3ph
H / V
11 14.4 20 10 x 3 + GND
11 13.2 20
6 x 3 +
480V
3ph
H / V
11 13.2 20 10 x 3 + GND
Connection table explanation and symbols
(*1) HEATING
(*2) EXPLANATION OF CONNECTION VALUES
H
Without heating
A x B + N +
Conductor cross-section in mm2
(A x B + GND)
(USA/CANADA: conductor cross-section in AWG)
E
Electric heating.
Consult TOTAL ELECTRICAL POWER
in the nameplate
A x B + N +
Wire number
V
Steam heating
A x B + N +
Neutral wire
A x B + N +
Ground
(A x B + GND)
(USA/CANADA: ground)
USE ONLY COPPER CONDUCTORS
ch.)