Troubleshooting
15. Empty Alarm Analysis
CFD2016S
1
With the drain valve open, check the drain
valve and drain plumbing for blockage.
The display reads
DID NOT
EMPTY.
Is
there voltage
(220 Volts) at the
drain valve?
Is
there voltage
(220 Volts) between
the blue and gray
wires going into
the drain
connection on the
main board?
YES
Replace the main board.
NO
YES
NO